Room temperature regulator without switch for supplementary heater
RTi 100 M
Designation
Wire 2
Wire (double)
Wire bl.
RTi 102 E
Designation
Wire 2
Wire 3
Wire (end sl. flat
connector) bl.
Wire (Cu-bridge)
Room temperature regulator with switch for supplementary heater
Designation
Litze (Endh.-Flachst.) bl.
• Tie switching wires from the switch in the cable harness (use twisters).
• Swing back the angle plate and screw tight.
• After installing the supplementary heater, the appropriate box in the circuit diagram in the right side
wall must be marked with a ballpoint pen.
• Fix the side wall, front wall and air outlet and inlet grilles back to the unit (in the right order!).
Fix the screws for the side wall and front wall with a toothed washer
(protective earth connection!)
2.3
Function Test
Change the temperature setting on the room temperature regulator until the fan switches on
(recognisable from the air outlet grille, hot or cold air depending on the charging state).
Switch on the supplementary heater at the ON/OFF switch in the control panel or on the external room
temperature regulator and check whether warmer air than before is blown out.
Check the power consumption of the supplementary heater.
2.4
Transfer
These operating and installation instructions are part of the unit and must be kept in a safe place by
the user. In the case of a change of ownership they must be handed over to the new owner.
The specialist must be given access to the operating and installation instructions for any repair work.
laying
of
according to
S1
LH' (X2)
S1
N6
N3
N (X2)
laying
of
according to
S1
LH' (X2)
S1
LH (X2)
N3
N (X2)
LE (X2)
LH' (X2)
laying
of
according to
N3
N (X2)
RTi 101 EP
Designation
laying
of
Double wire
S1
Wire double
S1
Wire bl.
N3
RTi 103 EP
Designation
laying
of
Wire 2
S1
Wire 3
S1
Wire (end sl. flat
N3
connector) bl.
For the Fitter
according to
LH (A3)
LH (X2)
S2
N (X2)
according to
LH (X2)
S2
N (X2)
19