For the Fitter
• Wire the heating element (9) and temperature regulator (N2) with the enclosed cable harness.
Plug the end of the cable harness to the temperature regulator (N2) with 2 flat connectors, plug the
other 2 flat connectors of the cable harness (arranged in the middle) to the heating element
connections and fix in the clip(s) from the underside of the air guidance assembly (similar to the
cables of the temperature regulator already installed in the unit). Push the loose end of the cable
harness through the front opening at the bottom of the intermediate wall (in the switching area).
• Replace the air flap (7) in the ventilation assembly, push the ventilation assembly into the unit (pull
the cable harness with silicone hose slightly into the switching area) and screw.
• Hang the angle plate back in the intermediate wall.
• Connect the loose end of the cable harness according to the following table (see also circuit
diagram) and fix the cable harness to the back of the angle plate (cable strap).
Designation
Wire (end sleeve)
Wire (flat connector)
• Connect the temperature regulator (N3) with a blue wire to N (X2) (see circuit diagram)
• The enclosed black wire (length L=150 mm) is only required in connection with one of the regulators
RTi 100 M, RTi 101 EP and RTi 103 EP (S1 and S2).
Note:
The wiring of the ON/OFF switch and the temperature regulator (N3) in connection with room
temperature regulators must be connected according to the following table.
The wiring depends on the room temperature regulator model (see circuit diagrams).
18
laying
of
cable harness
cable harness
to
LH (X2) connect from below
N3