You can view the exit delay time of the alarm centre in installer mode under
"Partitions".
For the "Instant" exit mode of the Secvest, a reception time of 5 seconds
applies for the wireless key-switch.
8.5. Partitions
To enter this submenu, press the program button (15) five times. The
display shows
. Keep the button pressed until the
appears on the
display.
When you program the first partition, the first position is shown by a
and
after about 1 second, the current programming is displayed (e.g.:
). You
can now change this number by pressing the button. A partition is active
when a
is displayed. A
indicates an inactive partition.
When the desired value is reached, press the button and keep it pressed
until
appears on the display. If you release the button, the second
partition is shown with
and you can continue input.
The 3rd partition is shown with
, and the 4th with
.
Program all 4 partitions in this way.
Important!
Set only those partitions to active (
) for which the user (code) is
authorised.
For information on assigning partitions to users, see the user menu of your
Secvest wireless alarm system under User Edit User Partition.
(Make sure you program the partitions that you have assigned to the user
at the wireless alarm system with the corresponding code.)
32