Technical Data - Clatronic BS 1286 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
Allow the foam and the fleece filter to dry completely in
the open air. Place the foam back onto the fleece filter
before you insert the motor protection filter into the dust
container.
CAUTION:
Never wash the filter in the washing machine, and
please do not use a hairdryer to dry it.
HEPA filter (15)
Your appliance also has a HEPA filter. It is located on
the rear side of the device beneath the parking hook
mount. In order to ensure that the filter works correctly,
we recommend that you replace it every six months.
1. Remove the mains plug from the socket.
2. Press the lever to the left and remove the ventilation
grid.
3. Remove the filter insert and clean it just like the fleece
filter of the motor protection filter (description see
above).
4. Set the filter insert back into the device in completely
dried condition.
5. Fasten the ventilation grid on the device. First press
the lever to the left again while doing so. Release it
as soon as the ventilation grid is completely mounted.
It has to audibly click in.
CAUTION:
Important note!
Cleaning may become necessary after a shorter time,
depending on the conditions of use, e.g. when vacuum-
ing fine dust.
If the suction power of your vacuum cleaner diminishes
please clean the filters as described.
If the suction power suddenly diminishes during opera-
tion this may be due to the filters being locked.
Cleaning & maintenance
WARNING:
Always remove the mains lead before cleaning!
Under no circumstances should you immerse the
device in water for cleaning purposes. Otherwise
this might result in an electric shock or fire.
CAUTION:
Do not use a wire brush or any abrasive items.
Do not use any acidic or abrasive detergents.
Clean the casing with a dry cloth.
Storage
Let the device cool down completely.
Wind the cable completely.
You may use the parking hook mount (14) on the rear
side of the device once you have installed the floor
nozzle (21) on the telescopic suction tube. Hang the
hook of the floor nozzle into the parking hook mount.
Troubleshooting
• The Device Does Not Work.
Renedy:
Check the connection to the mains.
Check the position of the switch.
• The device does not suck up anything.
Possible Cause:
The suction power is set too low.
Remedy:
Check the position of the control switch.
or
Possible Cause:
The dust container or the filters are dirty.
Remedy:
Empty or clean the components.
or
Possible Cause:
There is a foreign body in the suction tube or the
nozzle.
Remedy:
Check the accessories for foreign bodies.
Noise development
The sound pressure level in the ear of an operator (LpA)
was measured according to DIN EN ISO 3744.
Sound pressure level detected: 83.0 dB(A) (no limit)

Technical Data

Model: ................................................................. BS 1286
Power supply: ............................... 220 -240 V~, 50/60 Hz
Power consumption:
P
: ................................................................1800 W
nom.
P
: ............................................................... 2200 W
max.
Protection class: .............................................................. II
Net weight: ............................................... approx. 5.25 kg
The right to make technical and design modifications in
the course of continuous product development remains
reserved.
This device has been tested according to all relevant cur-
rent CE guidelines, such as electromagnetic compatibility
and low voltage directives, and has been constructed in
accordance with the latest safety regulations.
33

Publicité

Table des Matières
loading

Table des Matières