Installation
17 Installation
17.1 Suitable urinals
Use the ProDetect 2 only in combination with the following urinals:
Architectura 5586 / 5587 / 5574
•
Subway 7513
•
O.novo / Omnia 7507 / 7557 / 7527
•
17.2 Installing the hosing
S. 45
Advice!
Before opening the connected water line, you must ensure that the urinal control system
has previously been commissioned for a minimum of 30 seconds (power connection).
This applies to the battery and mains versions.
Advice!
Urinals with vertical discharge
Always use a mains model for urinals with vertical discharge.
We recommend installing the optional Bluetooth adapter. This will ensure simple operati-
on of the system without dismantling the urinal.
Advice!
At first installation of urinal and ProDetect 2
Carry out all necessary steps in the separate assembly instructions for fitting the urinal
•
before installing the hosing.
Flush the water line before installation to remove any contamination.
•
Before installing the hosing, make sure that the seals on the solenoid valve are arran-
•
ged correctly (see sketch).
Advice!
Retrospective installation of ProDetect 2
Before installing the hosing, remove the urinal attachments.
•
Flush the water line before installation to remove any contamination.
•
Before installing the hosing, make sure that the seals on the solenoid valve are arran-
•
ged correctly (see sketch).