Technical data PRO-ELYO INVERBOOST pool heat pumps
CE Standard, R410A, Heating and Cooling, inverter compressor, compressor defrosting, ABS Cabinet
Model
* Performance at Air 27℃, Water 26℃, Humidity 80%
Heating capacity
Power consumption
C.O.P.
* Performance at Air 15℃, Water 26℃, Humidity 70%
Heating capacity
Power consumption
C.O.P.
* Performance at Air 5℃, Water 26℃, Humidity 78%
Heating capacity
Power consumption
C.O.P.
* Performance at Air 0℃, Water 26℃, Humidity 78%
Heating capacity
Power consumption
C.O.P.
Rated water flux
Voltage
Maximum Current
Minimum Fuse
Current
Water in-out
connection
Fan quantity
Ventilation type
Compressor brand
Noise level at 1m
Net dimension
Net weight
Packing dimension
Gross Weight
* Above data are subjects to modification without notice.
3.
3.
3.
48710M
kW
20-4
kW
2.98-0.3
13-6.7
kW
14-3
kW
2.7-0.37
8.2-5.1
kW
11.5-2.5
kW
2.81-0.38
6.6-4.1
kW
9.2-2.0
kW
2.55-0.34
5.8-3.6
m
/h
6.00
3
230V/50/1PH
A
12.98
A
36
mm
2
Horizontal
MITSUBIS
HI
dB(A)
41-56
mm
Kg
108
mm
Kg
123
Specifications
Specifications
Specifications
48711M
48711T
26-6.8
26-6.8
3.88-0.52
3.88-0.52
13-6.7
13-6.7
19-5.4
19-5.4
3.6-0.66
3.6-0.66
8.2-5.2
8.2-5.2
15.6-4.4
15.6-4.4
3.75-0.68
3.75-0.68
6.6-4.2
6.6-4.2
12.5-3.6
12.5-3.6
3.40-0.61
3.40-0.61
5.8-3.7
5.8-3.7
8.00
8.00
380V/50/3PH 230V/50/1PH
17.07
11.43
47
31
2
2
Horizontal
Horizontal
MITSUBISH
MITSUBISHI MITSUBISHI
I
42-60
42-60
1050*452*1295
120
120
1130*515*1430
138
138
- 44 -
48712M
35-7
5.22-0.54
13-6.7
24-5.6
4.8-0.68
8.2-5
19.7-4.6
4.92-0.7
6.6-4.0
15.8-3.7
4.46-0.63
5.8-3.6
10.00
380V/50/3PH
23.08
63
50
2
Horizontal
MITSUBISHI
42-60
130
148
48712T
35-7
5.22-0.54
13-6.7
24-5.6
4.8-0.68
8.2-5
19.7-4.6
4.92-0.7
6.6-4.0
15.8-3.7
4.46-0.63
5.8-3.6
10.00
15.46
43
2
Horizontal
42-60
130
148

Hide quick links: