Caution!
While turning the union nuts (c), use an open-end spanner to hold the water volume
regulators (d) in place.
10.3 Remove the flush connector (e) and the existing seals.
10.4 Mount the fitting (f) with new seals.
10.5 Open the water volume regulator.
10.6 Check the water connections for leaks.
10.7 Mount the frame (g) horizontally.
10.8 If necessary, shorten the spacers (h) to fit between the front edge of the recessed
cabinet and the surface of the tiles.
10.9 Install the line connections between the electronic module, the solenoid valve unit
and the opto-sensor.
A: Solenoid valve unit
B: Connector for a sensor to be provided by the customer (e. g. door contactor)
C:Opto-sensor
D:Electric T-junction system lines (Power)
E: Electronic module
10.10 Optional: Connect the second sensor.
i ... Adapter line for sensors
k ... Door contactor
l ... yellow
m ... brown
10.11 Optional: Connect the third sensor.
i ... Adapter line for sensors
n ... Release for handicapped users
o ... white
p ... green (use in conjunction with 2/3 Y-sensor junction, core colour "yellow")
10.12 Hook-in the cover plate (r) on to the top of the tongues in the frame and attach.
10.13 Use the screws (s) to fix the cover plate at the bottom.
11. Function
11.1 Approach the sensor.
11.2 Remain in front of the WC flusher at least 5 s.
11.3 Walk away from the sensor and then press the release for handicapped users.
• Water flows.
• Water flow stops automatically after a set flow duration.
Flow duration
The flow duration has been factory-set to 10 s. The flow duration can be altered in
steps of 0.1 seconds, from 1-6500 s.
7