Storage
Store machines that are not in use in a dry locked place
protected against frost and outside the reach of children and
unauthorized persons.
Before a longer period of storage carry out the following to
extend the power pruner's service life and ensure an easy
operation:
Remove the battery
thoroughly clean the device
Remove the oil from the oil tank.
: Some chain oils tend to encrustations after a longer
period. For this reason the oil system should be
flushed before a longer storing with a chain saw
Before each fault elimination:
switch off device
wait for the power pruner to come to a standstill
remove the battery
After each fault clearance, put into operation and recheck all security installations.
Fault
Power pruner does not
start after switching on
Power pruner works
with interruptions
Power pruner picks,
vibrates or does not
saw correctly
Power pruner does not
work with full power
Saw chain gets hot
No
saw
chain
lubrication
Cutting time with fully
charged battery too
short
24
Possible cause
Li-Ion battery run down
Lithium-ion
battery
correctly
Li-Ion battery too cold/ too warm
Li-Ion battery, motor or switch defect
external loose connection
internal loose connection
ON / OFF switch defective.
Chain edgeless
Chain worn
Chain tension
Chain not assembled correctly (teeth
face to wrong direction)
The Li-Ion battery charge is low
The Li-Ion battery is defect
no oil in the tank
oil flow canal blocked
chain tension too high
Chain edgeless
no oil in the tank
oil flow canal blocked
Rechargeable battery is low
Battery service life exhausted
Chain soiled
Chain blunt/worn
Non chain lubrication
cleaner. Fill the cleaner up to the middle (approx. 50
ml) into the oil tank. Close the tank. Switch on the
power pruner without assembled guide bar and chain
until the complete cleaner has left the oil opening of
the power pruner.
Put the saw chain for a short time into an oil bath and
enwrap it afterwards in an oil paper.
Put the chain guard in place.
Refer to the respective "Operating instructions" for further
information on the batteries and the charger.
Possible faults
Remedy
Charge the Li- ion battery
not
inserted
Check whether the lithium battery has engaged audibly.
Allow the lithium battery to warm up/cool down
Have the battery, motor or switch checked / repaired by a
licensed electrician or customer service or replaced by
original spare parts.
Contact the customer service
Chain must be regrinded or exchanged
Exchange chain
Check and adjust chain tension
Assemble chain again
Charge the Li-Ion battery (manual battery "Charging the
battery"
Contact the costumer service
Refill oil
Clean oil flow canal
Adjust chain tension
Chain must be regrinded or exchanged
Refill oil
Clean oil flow canal
Charge the Li-Ion battery (Abschnitt „Akku laden")
Charging the rechargeable battery
Clean the chain
Chain must be reground or exchanged
Replenish oil (Section "Chain lubrication")