INSTALLATION MANUAL
KCPROXWLC
Dual Technology Digicode
/Proximity reader
®
1] PRODUCT PRESENTATION
Dual technology:
- Proximity reader,
- Digicode
keypad.
®
Output formats:
- Wiegand,
- Standard format,
- ISO Track 2 format.
Stainless steel.
Narrow: Ideal for installation
on aluminium profile.
Backlit.
Recommended for activating
and deactivating your alarm system.
Audible and visual feedback.
Power supplies: 12V dc.
Consumptions: 120mA.
2] NOTES & RECOMMENDATIONS
Operating modes
CENTAUR :
3 operating user modes with CENTAUR:
- Digicode
keypad only,
®
- Proximity reader only,
- or dual security (Proximity reader + Digicode
keypad).
®
The operating mode is programmed on Centaur software.
TERENA:
There are only 2 operating modes possible
on TERENA:
- Digicode
®
keypad,
- Proximity card reader.
Program the proximity card or the pin code
on TERENA software.
Cable
- Programming your installation before installing
products on site.
- The distance between a CTV900A (CENTAUR) controller
or AC22 (ATRIUM) controller and a KCPROXWLC
should not exceed more than 150 meters.
- Make sure not to exceed 50 meters between
the INTBUSW reader interface and the KCPROXWLC
Pin/Prox Digicode
®
.
cdvi.com
2
cdvigroup.com
CE Certification
IP64
Environmental tests:
vibrations
-25°C à +60°C
WEEE & RoHS
- Make sure that the cable is not near by a high
voltage cables (ex: 230 V AC).
- Recommended cable 2 twisted pairs (4 wires)
SYT1 0.8MM.
Back EMF protection
To secure the system from back electromagnetic
fields do not forget to mount the varistor in parallel
on the lock terminals.
Security Advice
- For security reasons, change the factory default
master code.
- When selecting a master code and user code
avoid simple codes (example : 3 4 5 6 7).
Mounting recommendations
Mount the keypad on a flat surface to avoid
any vandalism and to insure the best mounting.
Power Supplies
Recommended power supplies: ARD12 or BS60.
These products must be powered in 12Vdc and the
power supply should be certified EN60950-1:2006/
A11:2009 standards and should be designed to be
a low power supply source.
INSTALLATION MANUAL
EN
KCPROXWLC
Dual Technology Digicode
3] MOUNTING KIT
M5x8 Diax
screw
KCPROXWLC
4] MOUNTING INSTRUCTIONS
1
Place the back plate on the
wall then mark with a pen
the hole location then drill
the 2 mounting holes and
the hole wiring access.
5] WIRING EXAMPLE: KCPROXWLC TO A CONTROLLER
KCPROXWLC WIRING TABLE
Wiegand format
ISO2 format
Cables
outputs
RED
12VDC Input
12VDC Input
BLACK
0V
0V
Buzzer command
Buzzer command
BROWN
input
input
GREEN
DATA 0
CODE
WHITE
DATA 1
DATA
BLUE
CLOCK
CLOCK
PURPLE
PROGRAMMING
PROGRAMMING
YELLOW
GREEN LED
GREEN LED
ORANGE
RED LED
RED LED
/Proximity reader
®
®
T20 Diax
®
Plastic
Spanner
anchor
1
1
2
3
Insert the 2 plastic anchors
Insert the cable in the hole
in the holes.
access area of the back
Mount the back plate
plate. Then mount the
of the KCPROXWLC with the
keypad on the back plate.
screw on the wall.
Controller terminal wirings
Standard format
CTV900A
Outputs
Outputs
(CENTAUR)
12VDC Input
+12V
R1/0V
0V
R2/0V
Buzzer command
OUT5
OUT6
input
R1/D0
R2/D0
R1/D1
R2/D1
STANDARD – 1 WIRE
PROGRAMMING
OUT1
GREEN LED
OUT3
OUT2
RED LED
OUT4
EN
M4x30 screw
2
2
4
Fasten the KCPROXWLC
keypad to the back plate
with the M5x8 Diax
screw
®
and T20 Diax
spanner
®
hardware.
ONLINE SYSTEMS
AC22
INTBUSW
(ATRIUM)
+12V
12
GND
V
BUZ
7
D0
1
D1
3
2*
GRN
8
RED
9
* Optional
cdvi.com
3