Wood's LD40PRO Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 68
TECHNICAL DATA
Max working area
Air flow step 1
Dehumidifying at 20˚C and 70% r.h.
Dehumidifying at 30˚C and 80% r.h.
Power at 20˚C and 70% r.h.
Energy consumption at 20˚C och 70% r.h.
Tank volume
Refrigerant
Refrigerant change
Voltage
Frequency
Fuse
IP-class
Dimensions (L x W x H)
*Technical changes and improvements may occur. All values are approximate and may vary depending on external circumstances such as
temperature, ventilation and humidity.
PROBLEM
The dehumidifier does not start
The dehumidifier does not start
High noise level/rattling
No condensate water collected
Does not shut off when water tank is full.
If you have a problem with your dehumidifier, refer the troubleshooting guide. If none of the above works, contact your dealer to get your
dehumidifier serviced.
LD24
80 m
2
200 m
/h
3
6,5 L/24h
12 L/24h
160 W
4,3 kWh/24 h
11,4 liters
R290
99 g
230 V
50 Hz
10 A
X1
400 x 345 x 580 mm
REMEDY
• Make sure that the dehumidifier is connected to the socket and that the fuse has not blown.
• If the indicator light is red, check that the water tank is empty and correctly positioned in the dehumidifier. Ensure the
float hangs freely.
• Check that the hygrostat works by turning it up to max. The dehumidifier should then start within 5 min.
• Make sure the fan wheel is spinning.
• Make sure that the air can flow freely through the dehumidifier. Air emissions and air filters must be clean and the
dehumidifier must be at least 20-30 cm from the wall.
• Listen if the compressor is running, but keep in mind that the dehumidifier may be defrosting cycle and then the
compressor will stop. Start by waiting for about 30 minutes.
• Check that a thick layer of ice does not form on the cooling coils / slats behind the filter.
• Increase the distance between the dehumidifier and surrounding surfaces.
• The cooling coils may make contact to each other and cause vibrations. Disconnect the dehumidifier from the electrical
outlet and separate the loops
• Check that no dirt etc. is deposited on the drip tray underneath the cooling coils, clean if necessary.
• Check that the temperature is above 2 ° C or below 35 ° C.
• It is important that the float hangs freely in the water tank. If it does not, it does not sense the water level is and can
therefore not ensure that the dehumidifier stops
INSTRUCTIONS FOR USE
LD40PRO
180 m
2
300 m
/h
3
16 L/24h
31 L/24h
450 W
9,1 kWh/24 h
11,4 liters
R290
130 g
230 V
50 Hz
10 A
X1
400 x 345 x 580 mm
EN
07

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ld24

Table des Matières