HARD WIRING INSTALLATION

EN
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE
HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a qualifi ed electrician must remove the cord connection, and
wire the appliance directly to the household wiring. The wire and power supply breaker must rated for 120V
minimum 15 Amps.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In
the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the
current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
NOTE: There are 3 wires from the fi replace junction; white (neutral), black (power L1) and green
(ground) that connect to 120V power supply (breaker panel), see below.
* NEFB29H ILLUSTRATED
W415-1454 / B / 06.26.15
!
PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
WHITE
BLACK
GREEN
WARNING
WHITE
BLACK
GREEN
White, Green and
Black wires:
Connect to 120V
power supply.