Technical Data
Digital level
Article number
Length
Weight accord-
ing to EPTA-Pro-
cedure 01/2003
Digital level
Article number
Length
Weight accord-
ing to EPTA-Pro-
cedure 01/2003
DNM 60 L/DNM 120 L
Measuring range
Measuring
accuracy
– 0°/90°
– 1–89°
Levelling
accuracy of the
spirit level
Operating
temperature
Storage
temperature
Battery
Operating life
time, approx.
Please observe the article number on the
type plate of your measuring tool. The trade
names of the individual measuring tools
may vary.
Assembly
Inserting/Replacing
the Battery
Use only alkali-manganese batteries.
When the
symbol appears in the
display 6, the battery must be replaced.
Carefully remove the battery lid 1 with
the battery holder out of the measuring
tool. Pay attention that neither the con-
nection cables of the battery nor the
battery lid are damaged. Excessive
damage on the supporting surface of
the battery lid 1 can lead to faulty
measurements.
1 609 929 K06 • 12.6.06
DNM 60 L
PROFESSIONAL
3 601 K14 000
600 mm
0.7 kg
DNM 120 L
PROFESSIONAL
3 601 K14 100
1200 mm
1.3 kg
0–360° (4 x 90°)
±0.05°
±0.2°
±0.057°
(±1 mm/m)
–5 °C ... +50 °C
–20 °C ... +85 °C
1 x 9 V 6LR 61
200 h