Turn the measuring tool 180°
around the vertical axis so that the
spirit level still faces downward but the
display 6 is facing away from you. Wait
for 10 s.
Then press the "Calibrate" func-
tion button 9 again. "CAL2" is briefly
indicated in the display. Afterwards the
measured value appears in the display
(no longer flashing). The measuring
tool is now newly calibrated for both
horizontal surfaces.
Note: If the measuring tool is not
turned around the axis shown in the fig-
ure in steps
and
bration
cannot
("CAL2" is not indicated in the display).
Calibration for Vertical Surfaces
(see figure F)
The surface onto which you place the
measuring tool must not deviate from
the vertical line by more than 5°. If the
deviation is greater, the calibration
process is discontinued with the indi-
cation "---".
Switch the measuring tool on and
place it against the vertical surface in
such a manner that the spirit level 3
faces upward and the display 6 faces
you. Wait for 10 s.
Then press the "Calibrate" func-
tion button 9 until "CAL1" is briefly
indicated in the display. Afterwards the
measured value flashes in the display.
Turn the measuring tool by 180°
around the vertical axis so that the
spirit level still faces upward, but the
display 6 faces away from you. Wait for
10 s.
Then press the "Calibrate" func-
tion button 9 again. "CAL2" is briefly
indicated in the display. Afterwards the
measured value appears in the display
(no longer flashing). The measuring
tool is now newly calibrated for this
surface.
Afterwards you must calibrate the
measuring tool for the opposite sur-
face. For this, turn the measuring tool
around its horizontal axis in such a
manner that the spirit level 3 faces
downward and the display 6 faces you.
Place the measuring tool against the
vertical surface. Wait for 10 s.
20 | English
, then the cali-
be
completed
1 609 929 K06 • 12.6.06