With DIP9 in ON, the entry of terminal 25 (Stop/No panic) changes use.
By connecting a switch between 25 and 22, it is possible to DISABLE the
interlock function.
LEARNING
WARNING: During programming there must be no obstacles in the door's area or with-
in sensor's detection range, otherwise programming will fail and must be repeated.
The door can't be "helped" manually and the trimmers cannot be changed.
In case one of the following parameters are changed, programming must be repeated:
door leaves' travel, door leaves' weight, opening direction, (see DIP # 4 on SW2).
Press without releasing button P1 on the board. LED DL1 will start flashing yellow, and at the
same time the door will start opening and closing slowly to find the limit switches. At the end
the door will open and close at normal speed.
Once the travel setup is complete, the door must be closed and LED DL1 must flash green.
SENSOR TEST SETTING
•
Use only sensors which feature testing wires, connecting these to the wire terminals 5 and
6 of the controller DC13;
•
Set DIP # 7 and # 8 on SW1 to ON in order to enable the test;
•
Test will be performed at the beginning of each cycle (except when reversing motion).
LOGIC ADJUSTMENTS
Trimmer
Function
OPENING
TM1
SPEED
CLOSING
TM2
SPEED
OPENING
TM3
TORQUE
CLOSING
TM4
TORQUE
OPENING
TM5
SOFT STOP
CLOSING
TM6
SOFT STOP
AUTO CLOSE
TM7
DELAY
Dip switch SW1
1
EMERGENCY
2
ELECTRO-LOCK
Description
Adjusts Opening Speed.
Adjusts Closing Speed.
Adjusts Opening Torque.
Adjusts Closing Torque.
Sets the opening slowdown duration
Sets the closing slowdown duration
Adjusts Auto Close Delay.
ON
Enables opening with always closed program.
OFF Disables opening with always closed program.
Enables the electric lock when the automation is closed, regardless of
ON
the selected program.
Enables the electric lock when the automation is closed only with the
OFF
"always closed" program.
25