Télécharger Imprimer la page

tau DC17 Notice D'installation page 23

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
SM
0419
M1
M2
1
2
3
4
CONNECTOR J9 –
CONNECTOR J10–
Terminals
4
AUTOMATION OPEN LIGHT
5
POSITIVE
6
INTERLOCK OUTPUT
7
POSITIVE
CONNECTOR J11 – battery charger board connector.
CONNECTOR J12 – not used.
CONNECTOR J13 – battery connector.
CONNECTOR J14 – transformer primary connector.
CONNECTOR J15 – 230V 50Hz supply input connector.
Terminals
1
2
3
DFC PHOTOCELLS – CONNECTION
It is possible to connect up to 2 pairs of photocells using terminals 11 (power supply, brown
wires), 12 (common, blue wires), 9 (signal, black wire of the 1st pair receiver) and 15 (signal,
black wire of the 2nd pair receiver if used).
Important: if a 2
pair of photocells is connected, set DIP # 4 on SW1 to OFF.
nd
Black wire of the transmitter will not be connected.
Suggestions
HOLD OPEN =
WINTER OPENING =
AUTO =
EXIT ONLY =
LOCK =
electric block connection (12V DC).
output connection.
Input/Output
Input/Output
PHASE
GROUND
NEUTRAL
Keeps door fully open.
To have a reduced aperture.
All Opening Inputs enabled.
Disables Outside Radar.
Keeps door closed, allowing opening
only with EMERGENCY Input (with
Dip #1 on SW1 on ON).
Description
24V DC, max. 3 W
24v cc
24v cc
Description
230V AC
230V AC
23