SETTING THE TIMER

A) HOW TO SET THE OFF TIME
1. Press the PROGRAM button once.
The OFF and time indications flash.
2. Press the HH button until the designed hour
is displayed.
Press the MM button until the designed
minutes are displayed. The display will
change automatically back to show the
present time after 10 sec.
3. Press the ON/OFF button to start the air
conditioner.
4. Press the TIMER SELECT button to set
OFF time.
B) HOW TO SET THE ON TIME
1. Press the PROGRAM button twice.
The ON and time indications flash.
2. Press the HH button until the designed
hour is displayed.
Press the MM button until the designed
minutes are displayed. The display will change
automatically back to show the present time
after 10 sec.
3. Press the ON/OFF button to start the air
conditioner.
4. Press the TIMER SELECT button four times
to set ON time.
C) HOW TO SET A PROGRAM FOR DAILY
ON/OFF OPERATION (OR VICEVERSA)
1. Set the timer ON/OFF as shown in A) and
B).
2. Press the ON/OFF button to start the air
conditioner.
3. Press twice the TIMER SELECT button to set the ON/OFF
combination timer.
NOTE
After timer setting, press PROGRAM button in order to check the
ON/OFF setting time.
TIMER SETTING PROCEDURE.
Press the 1 HR TIMER button. The 1-HOUR ON TIMER mark
will appear on the display .
1-HOUR TIMER cancellation procedure.
• Press the ON/OFF button to turn the air conditioner off.
• Wait for the indoor unit to stop operating.
• Press the ON/OFF button again to turn the air conditioner on.
NOTES
COMBINING THE 1-HOUR TIMER AND THE DAILY PROGRAM
3
4
1
2

ADJUSTING THE AIR FLOW DIRECTION

HORIZONTAL (manual)
The horizontal air flow can be adjusted by moving the vertical
vanes to the left or right, as indicated in the following figures.
VERTICAL (with remote control unit)
Make sure that the remote control unit has been turned on. Press
the FLAP button to select the sweep function or to choose one of
the six positions of the flap.
Set vertical vanes to the front position during COOLING/DRY
operation if humidity is high.
If the vertical vanes are set to the left-most or right-most
position, condensation will form around the air outlet and
drip off.
Do not move the flap with your hands when the air conditioner
is running.
9
DISPLAY AFTER THE SETTING OPERATION
If the 1-HOUR TIMER button is pressed after a certain time
is elapsed from the setting operation, the 1-HOUR timer
function is activated again.
The 1-hour timer can be activated after the daily program
setting (par. C).
If the 1-HR TIME is pressed with the TIMER set in OFF
(
sign on the display) this setting will be cancelled as
the 1-HOUR TIMER is activated, the air conditioner runs for
1 hour and then it stops.
CAUTION
CAUTION
Left
Vertical vane
EG
Right