30" GAS RANGE INSTALLATION INSTRUCTIONS

Clearances and Dimensions

1. Location—Check location where the range will be installed. Check for proper electrical and gas supply, and the
stability of fl oor.
2. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface
must be solid and level.
Front View
7
29
/
"
8
3
36
/
"
8
±
1
/
"
4
Maximum
26"
46"
* 33" minimum clearance between the top of the cooking
surface and the bottom of an unprotected wood or
metal cabinet; or 24" minimum when bottom of wood
or metal cabinet is protected by not less than ¼" fl ame
retardant millboard covered with not less than no.
28 MSG sheet steel, 0.015" stainless steel, 0.024"
aluminum or 0.020" copper. The minimum clearance
is 0" for the rear of the range. Follow all dimension
requirements provided above to prevent property
damage, potential fi re hazard, and incorrect countertop
and cabinet cuts.
DO NOT MAKE ANY ATTEMPT
TO OPERATE THE ELECTRIC IGNITION OVEN
DURING AN ELECTRICAL POWER FAILURE.
RESET ALL OVEN CONTROLS TO OFF IN THE
EVENT OF A POWER FAILURE. The electric ignitor
will automatically re-ignite the oven burner when
power resumes if the oven thermostat control was
left in the ON position.
When an electrical power failure occurs during use,
the surface burners will continue to operate.
During a power outage, the surface burners can be
lit with a match. Hold a lighted match to the burner,
then slowly turn the knob to the Lite position. Use
extreme caution when lighting burners this way.
Typical cabinet installation
Front
view
36" Minimum*
8"
Minimum to
wall on either
side of range
above 36" height.
36"
30 1/8"
Avoid locating cabinet storage space above the surface
burners. Avoid locating cabinet storage space above
the surface burners. The absence of cabinets will
eliminate the chance of cabinets catching on fi re, and
eliminate the possibility of receiving personal burns
from reaching for the cabinets over fl aming surface
burners. If cabinet storage is to be provided, risk can
be reduced by installing a range hood that projects
horizontally a minimum of 5" beyond the bottom of
the cabinets.
Special instructions for appliances installed in the state
of Massachusetts: This Appliance can only be installed
in the state of Massachusetts by a Massachusetts
licensed plumber or gas fi tter. When using a fl exible
connector, it must not exceed three (3) feet (36 in.) long.
A "T" handle type manual gas valve must be installed in
the gas supply line to this appliance.
2
30"
Minimum to
18"
cabinets on
Maximum depth
either side
for cabinets
of range
above range top.
0" clearance below cooking top and at rear of range
Side
view
13"
25" Max.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fpgh3077rf

Table des Matières