• This device is not designed for uninterrupted operation. Frequent operation breaks will prolong the life of your
VDL80FB.
• Do not shake the device. Avoid brute force when installing or operating the device.
• Select a location where the device will be protected against extreme heat, moisture and dust. Respect a min.
distance of 50cm between the VDL80FB's light output and the illuminated surface
• Secure the device with an appropriate safety cable (VDLSC7 or VDLSC8).
• Do not use the device if the ambient temperature exceeds 45°C. The max. temperature for the housing is 130°C.
• Familiarise yourself with the functions of the device before actually using it. Do not permit operation by unqualified
people. Any damage that may occur will probably be due to unprofessional use of the device.
• Use the original packaging if the device is to be transported.
• Note that all modifications of the device are forbidden for safety reasons.
• Only use the device for its intended purpose. All other uses may lead to short-circuits, burns, electroshocks, lamp
explosion, crash, etc. Using the device in an unauthorised way will void the warranty.
4. Installation
a) Installing or Replacing a Lamp
CAUTION
: Only install a lamp when the device is unplugged from the mains and replace it if it has been
damaged in any way.
• The lamps can become extremely hot during operation, so you should let them cool down for at least 10 minutes
before replacing them
• Do not touch the halogen bulbs with your bare hands. Use a cloth to handle the lamps during insertion and
removal.
• Do not install lamps with a higher wattage as they generate higher temperatures than those for which the device
is designed.
• Use two lamps (230V/40W) with an E12 socket.
1. Unscrew the top of the housing where you will find the half ball with the coloured lenses.
2. Gently remove the half ball.
3. Remove the old lamp and insert the new one.
4. Carefully reposition the half ball.
5. Fasten the cover.
Note : Do not operate the device with an open cover!!
b) Mounting the Device
Remark
: Please consider the contents of EN 60598-2-17 and your own national norms during installation. A
qualified technician should carry out the installation!
• The supporting structure for the device must be able to carry 10 times the required weight for one hour without
deformation of that structure.
• The installation must always be secured by a secondary safety attachment e.g. a safety cable (VDLSC7 or
VDLSC8).
• Do not stand directly below the device when mounting, removing or servicing it. Have a qualified technician check
the installation once a year and once before you bring the device into service.