LCD Menu
The LCD controller has 4 buttons:
MENU: Page selection (different pages for different statuses)
UP: Increase the value / TIMER button
DOWN: Decrease the value / VOLUME button
ENTER: Enter/exit a menu item / STOP button
Press the MENU button to scroll through the 10 pages in total.
Page 1: Ready to fog.
Page 2: Interval setting
Set the interval of the TIMER mode between 5 and 200 sec.
Page 3: Duration
Set the duration of the TIMER mode between 5 and 200 sec.
Page 4: Timer Out
Set the output volume in TIMER mode between 1% and 100%
Page 5: Volume out
Set the output volume in VOLUME mode between 1% and 100%
Page 6: Fan Speed
Sett the fan speed from 1-100%
Page 7: Fluid sensor
Turn the "no fluid" protection function on and off.
Page 8: DMX512 address
The DMX address can be set from 1 to 512
Page 9: Wireless Set
Turn the wireless function on or off.
Page 10: Direct time
Turn the direct timer function on or off. When the unit is switched off and on again, it keeps the working mode of
when it has been switched off last time.
In all settings pages, press the ENTER / Stop button to exit or return to page 1.
During operation, press the ENTER / Stop button to stop operation and return to page 1.
Once you are in the settings page, change the value via the UP/DOWN buttons.
In page 1, press UP / TIMER button to enter into timer mode. The display switches between the settings below:
1. "Interval x sec."
2. "Duration x sec."
Interval and duration values are those set on page 2 and 3. The output volume in timer mode is set on page 4.
The display shows the count-down of the interval and then switches to the count-down of duration, etc.
When you are on page 1, press the DOWN / VOLUME button when "Ready to work" is displayed. The output volume
is the one that you have set on page 5.
DMX Function
When the unit is connected to DMX, the LCD display will show the address value. Press UP/DOWN buttons to
change the address.
DMX channels
Channel 1: Fan speed
0-10= Off; 11-255 increasing speed