Technical Specifications - RIB BRA111 Instruction Pour Le Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Pag. 8 di 12
RADIO CODE ACQUISITION
CARRY OUT WITH GATE CLOSED!
N.B. In the event of errors during the pushbutton operation procedure, repeat the
operation after resetting by wiring in Jumper for 1 second and then removing.
LED on
10 second interval to transmit
code settings by means of
remote control.
time?
SINGLE RADIO CODE CONFIRMATION
LED on
2s
10 second time interval to
transmit code to be cancelled
by means of remote control
2s
CHECK OF RADIO CODES ENTERED
LED on
2s
2s
maximum 59 codes (TX433)
maximum 29 codes (TX433 Rolling Code)
LED off
0,5s 0,5s
Four flashes indicate the end of the
time available to set codes.
Code not acquired
Code acquisition complete
the next pulse from the remote control
activates opening
LED off
Four flashes indicate end of time
allowed for cancellation of single code
code not cancelled
the cancelled code will by indicated
by one flash when transmitted
LED off
codes
entered
CANCELLATION OF ALL RADIO CODES ENTERED
LED on
2s
2s
Press S1 briefly
1 long flash
= signal not valid
1 short flash
= code saved or cancelled according to the procedure
selected
2 long flashes = code already present
2 short flashes = radio signals overlapped during setting
3 long flashes = memory full (max. 59 codes)
3 short flashes = memory empty, no code entered
4 long flashes
= end of time interval available to save or cancel a
single code
4 short flashes = code to cancel is not in memory
10 short flashes = setting locked
Long flash: Led ON for 0,5s
Short flash: Led ON for 0,25s
N.B. In addition to the code, the receiver also learns the channel to be
used; bear this in mind when pressing the pushbutton during the
self-learning procedure cause this pushbutton will henceforth
activate the system.
The control panel needs a tuned aerial 433,92MHz (code ACG5450) or
the range is reduced to just few meters.

TECHNICAL SPECIFICATIONS

Temperature range:
Humidity
Supply voltage
etc.
Frequency
Other
Maximum absorption of card (excluding accessories)
Transient mains power drops
Maximum power of the motor
Available current for photocell supply
IP class protection
Weight of apparatus
Overall dimensions
Volume
Reception frequency
Imput impedance
Sensitivity
Excitation time
De-excitation
LED off
2s
No cancel confirmation
2° 3°
3 flashes = memory
empty confirmation
L3 LED SIGNALS (Red)
0÷70°C
<95% without condensation
230V±10%
50/60Hz
20mS
0,5Hp
0.15A±15% 12Vdc
IP54
0,85Kg
14,7 x 6 x 18cm
1,6317dm
433,92MHz
52Ω
>2,24µV
300mS
300mS
23mA
3

Publicité