15. Specifi cation
● Power supply:
● Power consumption:
● Monitor Screen:
● Display Resolutions:
● Video signal:
● Wiring:
● Lock Power supply:
● Unlocking time:
● Monitor time:
● Talking time:
● Working temperature:
● Dimension for monitor:
● Dimension for door station:
17. Precautions
1) All components should be protected from violence vibration. And not allow to be
impacted, knocked and dropped.
2) Please do the cleanness with soft cotton cloth, please do not use the organic
impregnant or chemical clean agent. If necessary, please use a little pure water or
dilute soap water to clean the dust.
3) Image distortion may occur if the video monitor is mounted too close to magnetic fi eld
e. g. Microwaves, TV, computer etc.
4) Please keep away the monitor from wet, high temperature, dust, caustic and oxidation
gas in order to avoid any unpredictable damage.
5) Must use the right adaptor which is supplied by the manufacturer or approved by the
manufacturer.
6) Pay attention to the high voltage inside the products, please refer service only to a
trained and qualifi ed professional.
26Vdc +/- 2 (door station)
20 ~ 28Vdc (monitor)
Standby 6.5mA; Working status 180mA (monitor)
Standby 33mA; Working status 110mA (for door station).
4.3 inch digital color TFT
480(R, G, B) x 272 pixels
1Vp-p, 75Ω, CCIR standard
2 wires, non-polarity
12Vdc, 250mA (Internal Power)
1~99s (Default 3s)
40 seconds
90 seconds
-15ºC ~ 55ºC;
137(H)×137(W)×17(D)mm
145(H)×90(W)×23(D)mm (Without rain cover).