c) Mounting the Device
• Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms.
• The construction to which the device is attached should be able to support 10 times the weight of the device for
one hour without deformation.
• The installation must always be secured with a secondary attachment e.g. a safety cable (VDLSC7 or VDLSC8).
• Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified technician
check the device once a year and once before you bring it into service.
• Install the device in a location with few passers-by that is inaccessible to unauthorised persons.
• Overhead mounting requires extensive experience: calculating work load limits, determining the installation
material to be used... Have the material and the device itself checked regularly. Do not attempt to install the
device yourself if you lack these qualifications as improper installation may result in injuries.
• Adjust the inclination angle via the mounting bracket and tighten the bracket screws.
• Make sure there is no flammable material within a 50cm radius of the device.
• Have a qualified electrician carry out the electric connection.
• Connect the device to the mains with the power plug. Don't connect it to a dimming pack.
• The installation has to be approved by an expert before the device is taken into service.
5. Operating Instructions
Selecting the Start Address for the DMX Projector
All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This digital
start address is the channel number from which the device starts to "listen" to the digital commands from the DMX
controller.
You can use the same start address for a whole group of devices or enter an individual one for every device.
When using one single address, all the units will "listen" to the control signal on one particular channel. In other
words: changing the settings of one channel will affect all devices simultaneously. If you set different addresses,
each device will "listen" to a separate channel number. Changing the settings of one channel will only affect the
device in question.
In the case of the 1-channel VDP150CG, you will have to set the start address of the first device to 1, the second unit
to 2 (1 + 1), the third to 3 (2 + 1), and so on.
The LED next to the LED display indicates the status of the DMX signal. The LED flashes if the DMX signal is being
received and remains OFF if no signal is received.

Channel Configuration

CHANNEL 1 : choose colour + gobo, rainbow effect
You can use the included DMX cable to link multiple VDP150CG's for synchronous operation.

6. Cleaning and Maintenance

1. All screws should be tightened and free of corrosion.
2. The housing, the lenses, the mounting supports and the installation location should not be deformed or modified
or tampered with.
3. Mechanically moving parts must not show any signs of wear and tear.
4. The electric power supply cables must not be damaged. Have a qualified technician check the device.
VDP150CG
3
VELLEMAN

Publicité

Table des Matières
loading

Table des Matières