picture C1
STRADIVARI GRAN ROMANTICA MODEL
- Place the switch (5) on the on position; lighting
it up, will indicate that the machine is on, picture
C1.
- When the pointer of the pressure gauge (12)
will have reached the green zone, turn slowly
the steam tap knob (3) by turning it anticlokwise,
to discharge the "false pressure" due to the air
left in the boiler; then close it again by turning
it clockwise and wait for the pointer of the
pressure gauge to reach the green zone. Now
the machine has reached the correct pressure
and is ready to deliver coffee and steam. The
pressure will be automatically regulated and
maintained by the pressure switch which acts
on the heating element. The alternation of the
warning light (5) is normal because it means
that the pressure switch adjusts automatically
the pressure in the boiler.
- If during the operation the machine is left without
water, the safety thermostat will intervene by
interrupting the machine power supply. In this
case the thermostat will have to be reset (see
section 17 – Causes for Operating Failures).
48