WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Observe all governing codes and ordinances.
Required:
■
A 120 Volt, 60 Hz, AC only, 15- or 20-amp electrical supply
with a fuse or circuit breaker.
NOTES:
■
This is an optional step.
■
The anti-tip block (if installed) is to be provided by the installer.
Recommended Anti-Tip Block Dimensions
1" (2.5 cm)
4
Electrical Requirements
INSTALLATION INSTRUCTIONS
Install the Anti-Tip Block
¹⁄₂
3
"
(8.9 cm)
Recommended:
■
A time-delay fuse or time-delay circuit breaker.
■
A separate circuit serving only this microwave oven.
GROUNDING INSTRUCTIONS
■
For all cord connected appliances:
The microwave oven must be grounded. In the event of
an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric
current. The microwave oven is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded.
WARNING:
Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified
electrician or serviceman if the grounding instructions are
not completely understood, or if doubt exists as to whether
the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord is
too short, have a qualified electrician or serviceman install
an outlet near the microwave oven.
SAVE THESE INSTRUCTIONS
Anti-Tip Block Position
A. Anti-tip block
Using sturdy wood screws (installer to provide), securely install
the anti-tip block in the upper, right corner of the cutout, making
sure the block is completely stable. The bottom of the block must
be 14¹³⁄₁₆" (37.6 cm) from the cutout floor.
A
¹³⁄₁₆
14
"
(37.6 cm)