24" (61.0 CM) AND 30" (76.2 CM) MICROWAVE
DRAWER AND 27" (68.6 CM) TRIM KIT
INSTRUCTIONS D'INSTALLATION DU TIROIR À
FOUR À MICRO-ONDES DE 24 PO (61,0 CM) ET 30
PO (76,2 CM) ET DE LA TROUSSE DE GARNITURE
MICROWAVE DRAWER SAFETY ..................................................2
INSTALLATION REQUIREMENTS .................................................3
Tools and Parts .............................................................................3
Location Requirements ................................................................3
Minimum Dimensions...................................................................3
Electrical Requirements ...............................................................4
Cabinet Preparation .....................................................................5
Cabinet Preparation .....................................................................6
Cabinet Preparation .....................................................................7
Cabinet Preparation .....................................................................8
INSTALLATION INSTRUCTIONS ...................................................9
Install the Anti-Tip Block ..............................................................9
Install the Microwave Drawer .......................................................9
Complete Installation .................................................................10
ASSISTANCE ................................................................................10
IMPORTANT:
Installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANT :
Installateur : Remettre les instructions d'installation au propriétaire.
Propriétaire : Conserver les instructions d'installation pour référence
ultérieure.
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations
électriques.
W11257634B
TINSKB267MRR0
INSTALLATION INSTRUCTIONS
DE 27 (68,6 CM)
Table of Contents/Table des matières
SÉCURITÉ DU TIROIR À MICRO-ONDES .................................11
EXIGENCES D'INSTALLATION ...................................................12
Outillage et pièces ......................................................................12
Exigences d'emplacement .........................................................12
Dimensions minimales ...............................................................12
Spécifications électriques ..........................................................13
Préparation de l'armoire .............................................................14
Préparation de l'armoire .............................................................15
DE GARNITURE DE 27 PO (68,6 CM) .........................................16
Préparation de l'armoire .............................................................16
GARNITURE DE 27 PO (68,6 CM) ...............................................17
Préparation de l'armoire .............................................................17
INSTRUCTIONS D'INSTALLATION .............................................18
Installation du tiroir à micro-ondes ............................................18
installation en affleurement ........................................................19
Terminer l'installation ..................................................................20
ASSISTANCE ................................................................................20

Publicité

Table des Matières
loading

Sommaire des Matières pour Jenn-Air JMDFS24HM

  • Page 1: Table Des Matières

    24" (61.0 CM) AND 30" (76.2 CM) MICROWAVE DRAWER AND 27" (68.6 CM) TRIM KIT INSTALLATION INSTRUCTIONS INSTRUCTIONS D’INSTALLATION DU TIROIR À FOUR À MICRO-ONDES DE 24 PO (61,0 CM) ET 30 PO (76,2 CM) ET DE LA TROUSSE DE GARNITURE DE 27 (68,6 CM) Table of Contents/Table des matières MICROWAVE DRAWER SAFETY ..........2...
  • Page 2: Microwave Drawer Safety

    MICROWAVE DRAWER SAFETY...
  • Page 3: Installation Requirements

    Flush mount deflector (1) ■ Optional Parts 27" (68.6 cm) Trim Kit (W11170223) for JMDFS24GS ■ 27" (68.6 cm) Trim Kit (W11264778) for JMDFS24HM ■ Verification needed Installer must confirm presence of anti tip block. Refer to the ■ anti-tip block section in the manual.
  • Page 4: Product Dimensions

    " (4.1 cm) ■ JMDFS30HL Model - 1 " (4.3 cm) A separate circuit serving only this Microwave Drawer ■ JMDFS24HM Model - 1 " (4.4 cm) JMDFS30HM Model - 1 " (4.4 cm) GROUNDING INSTRUCTIONS Optional 27" (68.6 cm) Trim Kit: For all cord connected appliances: ⁵/₈...
  • Page 5: 24" (61.0 Cm) And 30" (76.2 Cm) Standard Mount

    " (395.27 mm) opening N. Allow 3/4" (19.05 mm) overlap O. JMDFS24GS Model - 1 " (41.28 mm) JMDFS30HL Model - 1 " (42.86 mm) JMDFS24HM Model - 1 " (44.45 mm) Top view JMDFS30HM Model - 1 " (44.45 mm)
  • Page 6: 24" (61.0 Cm) And 30" (76.2 Cm) Flush Mount

    P. 0" (0 mm) = flush Top view Q. JMDFS24GS Model - 1 " (41.28 mm) JMDFS30HL Model - 1 " (42.86 mm) JMDFS24HM Model - 1 " (44.45 mm) JMDFS30HM Model - 1 " (44.45 mm) R. 15 " (395.3 mm)
  • Page 7: 27" (68.6 Cm) Trim Kit Accessory Standard Mount

    27" (68.6 CM) TRIM KIT ACCESSORY STANDARD MOUNT (To be used with JMDFS24GS or JMDFS24HM) Cabinet Preparation Cabinet Dimensions A. 6" (152.40 mm) minimum 16" (406.40 mm) maximum B. Suggested electrical receptacle location C. Anti-Tip block Anti-Tip block D. 3" (76.20 mm) E.
  • Page 8: 27" (68.6 Cm) Trim Kit Accessory Flush Mount

    27" (68.6 CM) TRIM KIT ACCESSORY FLUSH MOUNT (To be used with JMDFS24GS or JMDFS24HM) Cabinet Preparation Cabinet Dimensions Note: The face of the shelf must sit 1⁷/₈" (47.6 mm) back from the face of the cabinet. Shelf face Cabinet face Flush mount de ector vent ³/₄"...
  • Page 9: Installation Instructions

    INSTALLATION INSTRUCTIONS Install the Anti-Tip Block Install the Microwave Drawer WARNING WARNING Excessive Weight Hazard Use two or more people to move and install microwave oven. Failure to do so can result in back or other injury. Crush Hazard 1. Empty Microwave Drawer of any loose contents. Microwave drawer can tip and fall out of opening.
  • Page 10: Install The Deflector Vent For Flush Installation

    9. Install four 1" (2.5 cm) screws to secure the Microwave 4. Guide the drawer into the prepared opening. Avoid contact Drawer in place, then close the drawer. with the sides of the cutout opening and also pinching the cord between the oven and the wall. 5.
  • Page 11: Sécurité Du Tiroir À Micro-Ondes

    SÉCURITÉ DU TIROIR À MICRO-ONDES Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité.
  • Page 12: Exigences D'installation

    Trousse de garniture de 27 po (68,6 cm) (W11170223) pour ■ JMDFS24GS Trousse de garniture de 27 po (68,6 cm) (W11264778) pour ■ JMDFS24HM Vérification à effectuer L’installateur doit vérifier qu’il y a bien une cale de bride ■ antibasculement. Consulter la section “Cale de bride antibasculement”...
  • Page 13: Spécifications Électriques

    (4,1 cm) ou 20 A, protégée par fusibles ou disjoncteur. JMDFS30HL modèle – 1 po (4,3 cm) Recommandation : JMDFS24HM modèle – 1 po (4,4 cm) JMDFS30HM modèle – 1 po (4,4 cm) Un fusible temporisé ou un disjoncteur temporisé.
  • Page 14: Support Standard De 24 Po (61,0 Cm) Et 30 Po (76,2 Cm)

    N. Permettre un chevauchement de Vue de dessus 3/4 po (19,05 mm) O. JMDFS24GS modèle – 1 po (41,28 mm) JMDFS30HL modèle – 1 po (42,86 mm) JMDFS24HM modèle – 1 po (44,45 mm) JMDFS30HM modèle – 1 po (44,45 mm)
  • Page 15: En Affleurement De 24 Po (61,0 Cm) Et 30 Po (76,2 Cm)

    P. 0 po (0 mm) = en affleurement Q. JMDFS24GS modèle – 1 po (41,28 mm) JMDFS30HL modèle – 1 po (42,86 mm) JMDFS24HM modèle – 1 po (44,45 mm) JMDFS30HM modèle – 1 po (44,45 mm) R. 15 po (395,3 mm)
  • Page 16: Support Standard Pour Trousse De Garniture De 27 Po (68,6 Cm)

    L. La plateforme doit supporter 100 lb (45,4 Tiroir Garniture M. Ouverture de 15 po (395,27 mm) visage N. Permettre un chevauchement de 3/4 po (19,05 mm) O. JMDFS24GS modèle - 1 po (41,28 mm) JMDFS24HM modèle - 13/4 po (44,45 mm) Vue de dessus...
  • Page 17: En Affleurement Pour Trousse De Garniture De 27 Po (68,6 Cm)

    N. La plateforme doit supporter 100 lb (45,4 kg) visage visage Garniture O. 16 po (409,56 mm) P. 0 po (0 mm) = en affleurement Q. JMDFS24GS modèle - 1 po (41,28 mm) JMDFS24HM modèle - 13/4 po (44,45 mm) Vue de dessus R. 15 po (395,3 mm)
  • Page 18: Instructions D'installation

    INSTRUCTIONS D’INSTALLATION Installation de la cale de bride antibasculement AVERTISSEMENT " ¹³⁄₁₆ (37,6 cm) Risque d’écrasement Le tiroir à micro-ondes peut basculer et tomber de l’ouverture. Fixer la cale de bride anti-basculement au mur, A. Bloc Anti-Tip conformément aux instructions d’installation. À...
  • Page 19: Installer Le Déflecteur D'évacuation Pour Une Installation En Affleurement

    Détail de la tablette montrant le déflecteur d’évacuation pendant AVERTISSEMENT l’installation. Risque de choc électrique Brancher sur une prise à 3 alvéoles reliée à la terre. Ne pas enlever la broche de liaison à la terre. Détail de la tablette montrant le déflecteur d’évacuation installé. Ne pas utiliser un adaptateur.
  • Page 20: Terminer L'installation

    Terminer l’installation ASSISTANCE 1. Contrôler le fonctionnement du tiroir à micro-ondes : placer Appelez le marchand local autorisé ou le centre de service dans le tiroir à micro-ondes 1 récipient contenant 1 tasse agréé. Lors de votre appel, vous aurez besoin des numéros de (250 ml) d’eau et programmer une période de chauffage de modèle et de série du tiroir à...