9. Specifications
Specifications
Shock resistance
EN
Service life
Ingress protection (per
IEC 60529)
Mounting position
Electrical connections
Plug connection
Short-circuit resistance
Reverse polarity protection
Insulation voltage
Overvoltage protection
Pin assignment
Materials
Wetted parts
Non-wetted parts
Case
Circular connector M12 x 1, metal
Circular connector M12 x 1
LED status display
Pressure transmission medium
22
100 g, 6 ms (IEC 60068-2-27, mechanical)
1,000 g, 1 ms (IEC 60068-2-27, mechanical) for electrical connection, M12 x 1, metal
100 million load cycles (10 million load cycles for measuring ranges > 600 bar/7,500 psi)
see "Electrical connections"
as required
Circular connector M12 x 1, metal (4-pin), IP65 and IP67
Circular connector M12 x 1 (4-pin), IP65 and IP67
Angular connector DIN 175301-803 A (3-pin), IP65
The stated ingress protection (per IEC 60529) only applies when plugged in using mating
connectors that have the appropriate ingress protection.
SP1/SP2 vs. U-
U+ vs. U-
DC 500 V
DC 36 V
see product label
Stainless steel
316L
316L
PBT GF30
PC
Synthetic oil for all gauge pressure measuring ranges < 10 bar [150 psi] and all absolute
pressure measuring ranges.
< 16 bar [250 psi] with increased overload safety
WIKA operating instructions, pressure sensor, model A-1200