6 6
6Safety6Notes
6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 With water heaters of 5 liters the flow rate at the
mixer should not exceed 5 l/min.
6 In this case the flow rate must be reduced at the
isolation valve.
Installation6Instructions
• The fitting must be installed, flushed and tested after
the valid norms!
• Connect the shorter, blue marked supply pipe to the
angle valve. Connect the longer blue marked pipe
to the inlet and the red marked to the outlet of the
storage tank.
• If necessary shorten platic hose according to the
table and insert it up to the collar into the shorter blue
marked copper pipe.
Technical6Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow:
6
English
Symbol6description
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 5 l/min
Assembly6see6page660
Do not use silicone containing acetic acid!
Dimensions6(see page 62)
Spare6parts6(see page 64)
When changing the spray former, it is
imperative to use one made for this type of
mixer.
Special6accessories
special tool (58085000) order as an extra
Installation kit order as an extra
Operation6(see page 63)
When the storage tank is being heated, the
spout will drip.
Cleaning
see enclosed brochure.