FLEXIBLE LAMP
The flexible lamp op er ates in de pen dent ly of the drill press. To turn the lamp "ON" and "OFF", rotate switch (A) Fig. 26.
FIRE HAZARD. To reduce the risk of fire,
use a 40 watt or less, 120 volt, reflector track-type
light bulb (not supplied). DO NOT USE a standard
house hold light bulb. Do not allow the reflector track-
type light bulb to extend below the lamp shade.
RISK OF PERSONAL INJURY. Disconnect
the machine from the power source before making
any adjustments.
TABLE ADJUSTMENTS
RISK OF PERSONAL INJURY. Make sure that nothing is on the table and that the workpiece is clamped
down. Falling objects can cause an injury.
You can tilt the table forward from zero (0) to 45 degrees. To adjust:
1. Loosen the two forward tilt levers (A) Fig. 27.
2. Adjust the table to your desired angle. The scale (B) Fig. 27 is located on the side of the table support.
3. Tighten the levers (A) Fig. 27.
4. A positive stop (C) Fig. 28 is provided to return the table to the zero position. Adjust this stop by turning the screw/
stop (C), located under the table. Tighten the locknut to secure the stop.
You can tilt the table right or left. Positive stops are included for 0, 45 and 90 degrees. To adjust:
1. Loosen the table bolt (E) Fig. 29 approximately 1/4 turn with the supplied 12mm hex wrench.
2. Pull out the spring-loaded detent pin (F).
3. Rotate the table to your desired angle. The tilt scale (G) Fig. 30 is located on the knuckle behind the table. Use this
scale for accuracy. You can allow the detent pin to slide in to the positive stops (0, 45, and 90 degrees), but check
your scale to be sure of the exact angle.
4. Tighten the table bolt.
B
Fig. 27
E
F
A
Fig. 29
14
C Located under table
Fig. 30
A
Fig. 26
Fig. 28
G