Troubleshooting
SYMPTOM
Pump does not run when water
flows in from sink
Pump runs, but does not empty
sink
Pump cycles on and off when
no water is in the sink
Pump cycles on and off when the
sink is at maximum water
flow or is full
ATTACH ORIGINAL RECEIPT HERE FOR WARRANTY CONSIDERATION.
FLOTEC warrants to the original consumer purchaser ("Purchaser") of its products that they are free from defects in material or workmanship.
If within twelve (12) months from the date of the original consumer purchase any such product shall prove to be defective, it shall be repaired or
replaced at FLOTEC's option, subject to the terms and conditions set forth below. Your original receipt of purchase is required to determine war-
ranty eligibility.
Exceptions to the Twelve (12) Month Warranty
Product
Drill Pump, Pitcher Pump, In-line Water Filter Cartridge
1/3 HP Submersible Sump Pumps, I
Back-up Sump Pump System (Model FP2800DCC)
4" Submersible Well Pumps, 1/2 HP Submersible Sump Pumps
Models FPSC2200A-10 and FPSC2250A-10
Pre-Charge Water System Tank, Models FPSC3200A-10 and FPSC3250A-10
Floodmate
®
7000 (Model FP0S6000A), Ironmate
Sewage Ejector (Model FPSE3601A), Pedestal Sump Pump (Model FPPSS5000)
Utility Pump (Model FPSC1725X), Submersible Sump Pump (Model FPSC4550A-10)
General Terms and Conditions
Purchaser must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty shall not apply to
acts of God, nor shall it apply to products which, in the sole judgement of FLOTEC, have been subject to negligence, abuse, accident, mis-
application, tampering, alteration; nor due to improper installation, operation, maintenance or storage; nor to other than normal application,
use or service, including but not limited to, operational failures caused by corrosion, rust or other foreign materials in the system, or opera-
tion at pressures in excess of recommended maximums.
Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to FLOTEC as soon as pos-
sible after the discovery of any alleged defect. FLOTEC will subsequently take corrective action as promptly as reasonably possible. No
requests for service under this warranty will be accepted if received more than 30 days after the term of the warranty.
This warranty sets forth FLOTEC's sole obligation and purchaser's exclusive remedy for defective products.
FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES,
INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR-
POSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty
lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other
rights which vary from state to state.
E-Mail: info@flotecwater.com • Web Site: http://www.flotecwater.com
For parts or assistance, call Flotec Customer Service at
POSSIBLE CAUSE(S)
Pump unplugged.
Outlet unpowered.
Pump impeller jammed.
Sink stopper in drain.
Drain clogged.
Clogged discharge line.
Shut-off valve closed.
System discharge line too
high or too long.
Check valve installed
backwards
Check valve not installed.
Check valve jammed.
Shut-off valve not adjusted.
Shut-off valve not installed.
P
(Model FP0S1775A)
NTELLI
UMP
®
(Model FPSC4550A)
FLOTEC • P.O. Box 342 • Delavan, WI U.S.A. 53115
Phone: 1-800-365-6832 • Fax: 1-800-526-3757
CORRECTIVE ACTION
Plug in pump.
Check fuse / breaker.
Unplug pump; follow procedure under "Maintenance"
to clear pump.
Remove stopper.
Clear drain screen.
Unplug pump, open and clear discharge line.
Open shut-off valve slightly.
Unplug pump and reduce height or length of discharge line
(11' Max. Height).
Make sure flow arrow on check valve points away
from pump.
Unplug pump and install check valve (see Figures 2
and 3, Pages 3 and 4).
Unplug pump; open discharge line and clean check valve.
See "Adjusting the Flow", Page 3.
Unplug pump and install shut-off valve (see Figures 2
and 3, Pages 3 and 4).
1-800-365-6832