C.
A..
Figure 4 – Screen display in detection mode
4 - To change settings you need to tap the touch screen – a tools icon
lower left corner of the screen. Tap the tools icon and the following screen will open up.
Tap the following icons to adjust the settings as indicated below.
Frequency (512 Hz, 640 Hz, 50/60 Hz passave, 33 KHz active/passive)
Auto shut-off (10 min / 20 min / 30 min / never)
Headlights (no / off)
Unit of measure (English / Metric)
Volume (off / half / on)
Depth (single measurement / average – multi measurement)
Return to horizontal display (below)
5- Once you have reached the place where the signal is the strongest (this means you are above
the emitter/SONDE), press the enter button to switch the visual display to depth mode which
shows the approximate depth of the emitter/SONDE. Press the enter button once more to return to
the horizontal display.
14
A. Signal strength (numbers and emitter waves)
B. Indicator arrows
C. Probe frequency
B..
No information available:
User may encounter this reading if emitter/SONDE
is below or beyond range of locator (0,6 – 1,8m).
Figure 4 – Tools menu