Long-term storage(30 days or more)

During operation the silencer - catalytic silencer and surrounding cover become hot. Always keep exhaust
area clear of flammable debris during transportation or when storing, otherwise serious property damage
or personal injury may result.
Do not store your unit for a prolonged period of time (30 days or longer) without performing protective storage maintenance which
includes the following:
1. Stop switch
1. Spark plug
Please contact your shindaiwa dealer in order to dispose of the product or its parts in compliance with national laws.
WARNING
2. Spark plug cap
Maintenance and care
1.
Store unit in a dry, dust free place, out of the reach of chil-
dren.
Do not store where fuel fumes may accumulate or reach an
open flame or spark.
2.
Place the stop switch in the "STOP" position.
3.
Remove accumulation of grease, oil, dirt and debris from ex-
terior of unit.
4.
Perform all periodic lubrication and services that are re-
quired.
5.
Tighten all screws and nuts.
6.
Drain the fuel tank completely and pull the recoil starter han-
dle several times to remove fuel from the carburettor.
7.
Remove the spark plug and pour 10mL of fresh, clean shin-
daiwa 2-stroke engine oil into the cylinder through the spark
plug hole.
A. Place a clean cloth over the spark plug hole.
B. Pull the recoil starter handle 2-3 times to distribute the
oil inside the engine.
C. Observe the piston location through the spark plug hole.
Pull the recoil handle slowly until the piston reaches the
top of its travel and leave it there.
8.
Fit the spark plug. (Do not connect the spark plug cap. )
9.
Remove blower pipe assembly from unit.