• All the heaters are fitted with switch and high temperaure silicone
rubber flexible cable (H05 RN-F) conforming to BS 6500.
• The product is in class I and IP65, wich is the protection rate for
the units to be used even outdoor. For keeping the protection rate
of the appliance, the connection of the appliance with the power
supply must be done by means of a minimum IP65 system, as per
the standards HD 384 CENELEC for Europe, or international IEC
60346-7-708 1988.
3. LOCATION
While fastening the appliance to the wall or to the upright,
be careful that the slots (fig. 2-D) of the bracket be at the
bottom.
The SOMBRA range of heaters is deliberately designed to be very
flexible in the choice of position. There are two basic options:
• Wall mounting bracket (fig. 3). Before drilling the holes for the
dowels, be sure that the wall is solid and that you are far from wa-
ter tubes or electrical wires. For fixing the appliance at the wall, drill
3 holes with a 5 mm diameter bit and fix the wall bracket (fig. 2-A)
that you find in the box by proper dowels and screws, ensuring
that the slots (fig. 2-D) be at the bottom. Then adjust the angle of
the appliance; at last make it firm tightening the sideward screws
(fig. 2-C).
• Mounting on upright (fig. 4) or patio umbrella (fig. 5). The appli-
ance can be fastened to a upright or to the ribs of a patio umbrella,
by the optional upright bracket (code 4165.792 – fig. 2-B). The
section of the upright or the ribs can be circular with diameter be-
tween 20 and 45 mm, or square with side between 18 and 33 mm.
The mounting options are shown in fig. 7. Before tightening the 2
rear knobs to fasten the bracket, ensure that the slots (fig. 2-D) be
at the bottom. Then adjust the angle of the appliance; at last make
it firm tightening the sideward screws (fig. 2-C).
Before fixing the appliance on the upright, please ensure that
it is stable and solid. In case the Tripod is used, its feet must
be opened as far as the white evidenced line on the infe-
rior tube reaches the junction of the feet. Fix the feet to the
12