LED display

LED 1
LED 2
Fig. 3-2:
Position of the BTL7 LED displays
LED 1
Green
Normal function
Magnet is within the limits.
Red
Error
No magnet or magnet outside the limits.
LED 2
Green
Synchronous operation
Internal measurement is synchronous to SSI
query.
Off
Asynchronous operation
Internal measurement is asynchronous to SSI
query.
Programming mode
Flashing
green
Only with BTL7-S510...
Note on configuration
(only BTL7-S510...)
The entire range of functionality can only be
configured with the PC software BTL7
Configuration Tool. To do this, the USB
communication box must be connected
(see Accessories on page 23).
When reading or writing data via the BTL7 Configuration
Tool, LED 2 flashes green to display programming mode.
1)
Asynchronous operation is reached when the external sampling rate is
> f
or < 62.5 Hz (only with BTL7-S5_ _B/F-...), see Technical data on
A,max
page 20, Fig. 8-1.
8
english
1)
1)
Behavior of LED 1 and the error value through the entire
range:
SSI
out
LED
21
2
Magnet
missing
≈ 5 mm
0
Null point
Fig. 3-3:
Behavior of LED 1 and error value BTL7 ≥ 5 µm
BTL7-S5_ _-... and BTL7-S5_ _B-... :
For resolutions ≥ 5 µm, in the case of an error, bit 2
set. For resolutions < 5 µm, there is no error bit and the
value 0 is output.
BTL7-S5_ _E-... and BTL7-S5_ _F-... :
The error bit is not available and the value 0 is output.
Pos
End point
is
21

Publicité

Table des Matières
loading

Table des Matières