OBJ_BUCH-2301-002.book Page 38 Monday, December 22, 2014 10:15 AM
38 | English
Adjusting: (see figure U2)
– Loosen the lock nut of the stop screw 63 using a conven-
tional ring spanner or open-end spanner (10 mm).
– Screw the stop screw in or out until the leg of the angle
gauge is flush with the saw blade over the complete length.
– Tighten clamping lever 7 again.
– Then retighten the lock nut of the stop screw 63.
When the angle indicators 43 and 5 are not in line with the 45°
marks of scale 4 after adjusting, firstly once more check the
0° setting for the bevel angle and the angle indicators. Then
repeat the adjustment of the 45° bevel angle.
Setting the Standard 45° Bevel Angle (Rightward)
– Bring the power tool into the working position.
– Turn the saw table 19 to the 0° detent 26. The lever 23
must be felt to engage in the detent.
– Remove the right-hand adjustable fence 2 (see "Moving
the Fence", page 34).
– Pull the stop 44 completely forward.
– Turn the right-hand stop 3 until the standard 45° bevel an-
gle engages at the arrow mark.
– Loosen clamping lever 7.
– Swing the tool arm to the right by the handle 12 until the
stop screw 64 rests on the stop 3.
Checking: (see figure V1)
– Set an angle gauge to 135° and place it on the saw table 19.
The leg of the angle gauge must be flush with the saw blade 48
over the complete length.
Adjusting: (see figure V2)
– Loosen the lock nut of the stop screw 64 using a conven-
tional ring spanner or open-end spanner (10 mm).
– Screw the stop screw in or out until the leg of the angle
gauge is flush with the saw blade over the complete length.
– Tighten clamping lever 7 again.
– Then retighten the lock nut of the stop screw 64.
When the angle indicators 43 and 5 are not in line with the 45°
marks of scale 4 after adjusting, firstly once more check the
0° setting for the bevel angle and the angle indicators. Then
repeat the adjustment of the 45° bevel angle.
Aligning the Scale for Mitre Angles
– Bring the power tool into the working position.
– Turn the saw table 19 to the 0° detent 26. The lever 23
must be felt to engage in the detent.
Checking: (see figure W1)
– Adjust an angle gauge to 90° and position it between the
fence 1 and the saw blade 48 on the saw table 19.
The leg of the angle gauge must be flush with the saw blade 48
over the complete length.
Adjusting: (see figure W2)
– Loosen all four set screws 65 with the hex key (4 mm) 38
and turn the saw table 19 together with the scale 27 until
the leg of the angle gauge is flush with the saw blade over
the complete length.
– Retighten the screws again.
1 609 92A 0Z5 | (22.12.14)
When the angle indicator 25 is not in line with the 0° mark of
scale 27 after adjusting, loosen screw 66 with a cross-head
screwdriver and align the angle indicator alongside the
0° mark.
Transport (see figure X)
Before transporting the power tool, the following steps must
be carried out:
– Loosen the locking screw 6 if tightened. Pull the tool arm
completely to the front and tighten the locking screw
again.
– Make sure that the depth stop 41 is swung completely
backward and that the adjusting screw 40 fits through the
recess without touching the depth stop when moving the
tool arm.
– Bring the machine into the transport position.
– Remove all accessories that cannot be mounted firmly to
the power tool.
If possible, place unused saw blades in an enclosed con-
tainer for transport.
– Wind up the mains cable and tie it together with Velcro
strap 67.
– Carry the machine by the transport handle 10 or hold it by
the recessed handles 29 on the sides of the saw table.
The power tool should always be carried by two per-
sons in order to avoid back injuries.
When transporting the power tool, use only the trans-
port devices and never use the protective devices.
Maintenance and Service
Maintenance and Cleaning
Before any work on the machine itself, pull the mains
plug.
If the replacement of the supply cord is necessary, this has to
be done by Bosch or an authorized Bosch service agent in or-
der to avoid a safety hazard.
Cleaning
For safe and proper working, always keep the power tool and
its ventilation slots clean.
The retracting blade guard must always be able to move freely
and retract automatically. Therefore, always keep the area
around the retracting blade guard clean.
Remove dust and chips after each working procedure by
blowing out with compressed air or with a brush.
Clean the roller 16 regularly.
Measures for Noise Reduction
Measures on behalf of the manufacturer:
– Soft starting
– Delivery of the machine with a saw blade developed partic-
ularly for noise reduction
Measures on behalf of the user:
– Low-vibration assembly on a firm working surface
– Use of saw blades with noise-reducing functions
– Regular cleaning of saw blade and power tool
Bosch Power Tools