Before installing, carefully read the Recommendations and Safety standards in order
to avoid a certain number of problems.
If you want to move your freezer, hold it by the sides or by the base. You should never lift it
by its top.
Install the appliance in a dry, well-ventilated room, away from all sources of heat. Leave a
minimum gap of 10 cm between the top of the freezer and any wall-mounted kitchen units. If
this is impossible, leave 5 cm above the appliance and 2.5 cm on each side of the appliance.
Make sure that the air vents on your freezer are not covered or blocked.
The climate class of your freezer is marked on its ID plate. It determines the range of
ambient temperatures for which the cooling unit is designed, and within which correct
operation of the appliance is guaranteed.

Electrical connection

Connector characteristics: 220-230V with earth.
Avoid using adapters or extension leads.
Avoid the cable coming into contact with the compressor.
Avoid trapping the cable under the appliance.
The appliance's electrical installation is earthed. For your safety, connect the appliance to a
power outlet with effective earthing (in conformity with current electrical installation safety
standards).
The manufacture declines all liability for damage caused by the absence of an earth
connection.
CAUTION – BEFORE CONNECTING
1. Clean the inside of the freezer with warm water containing bicarbonate of soda. Rinse and
dry thoroughly.
2. Wait for 2 hours before switching on, to ensure that the lubricants in the motor
compressor have stabilised.

INSTALLATION

Class
Ambient temperatures
N
ST
T
16° to 32°
18° to 38°
18° to 43°