Align the 2 locating arrows
marked on the mounting
base and the detector, then
lock the unit by turning
clockwise.
CAution: the detector
cannot be fixed to the base
if the battery is not properly
seated.
Do not use force.

4.4 installing several detectors in a network

It is possible to inter-connect up to 40 detectors to enable
alarm activation over the whole range of smoke detectors of
the home. You can therefore be sure of being warned if
smoke is detected in a room far away from the room in which
you are in.
1. After the detector's mounting base has been installed
(see Mounting), unfasten the connector block.
Connector block
2. Then wire as follows:
Cable
terminals
Not used
For a wire of 1.5 mm
must not exceed 400 m.
3. Fix the connector block back onto the mountting base.
4. Lock the detector on its base (see Mounting).
CAution: connect only detectors of the same model
within the network.
42
Signal
Common
2
section the total length of the network