Establishing The Electrical Connection En; Connection Side Han 16A En; Terminal Strip X1 En - Abicor Binzel BRS-LCi Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BRS-LCi
For adjusting the spray quantity, the system must be provided with compressed air. In order to assess the
function and the spray quantity, the solenoid valve Y3 must be switched.
 Abb. 14 Connecting the pneumatic system on page EN-18
Danger of crushing
Limbs can be drawn in and crushed by moving parts (milling cutter, clamping unit).
• Do not reach between moving parts.
Damage to the eyes
Sprayed release agent may damage the eyes.
• Wear safety goggles.
• Only adjust release agent by switching the solenoid valve Y3.
1 Connect siphon hose (5) to the release agent cylinder if necessary.
2 Switch on Y4.
3 Adjust the quantity of release agent by means of the adjusting screw (4).
4 Switch off Y4.
6.9 Establishing the electrical connection
Four robot outputs 24 V DC and one robot input are required for controlling the valves.
6.9.1 Connection side HAN 16A
GND
PE
Abb. 11
Connection side HAN 16A
BAL.0149.0 • 2017-05-17
WARNING
WARNING
Voltage supply
n.c.
HAN16A
16 pins
1
n.c.
Terminal strip X1
GND
Proximity switch
Switching outputs Valve coils
24VDC
4
7
10 9
8
5
4
6 Putting into operation
6
12
13
EN - 15

Publicité

Table des Matières
loading

Table des Matières