External Battery Connection Procedure; Bypassing The Internal Battery - Wagan Tech SOLAR e POWER CUBE 1500 PLUS Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Solar e Power™ Cube 1500 Plus by Wagan Tech
use. Connecting flooded, GEL or lead–calcium batteries can, over time, result in uneven charge
and discharge between the internal and external batteries, a battery damaging condition. You
may temporarily connect flooded, GEL or lead–calcium batteries to the Solar e Power Cube.
It is important that you only connect same voltage (12V) batteries in parallel. Reverse polarity
connections can cause an explosion. Connecting external batteries to the Solar e Power Cube in
series could cause damage to the system and void the warranty. It is recommended that adding
batteries be performed by a qualified person. If in doubt, a user-provided voltmeter may be
needed to verify voltage and polarity of external batteries to be connected to Solar e Power
Cube.
CAUTION—exTerNAL BATTery:
• When adding batteries to the system for long-term use, you must use 12V AGM batter-
ies. Using different construction or chemistry batteries can damage components.
• The supplied 5 amp rated AC charger has a total amp hour limit. External batteries
may not exceed 240 amp hours. Total internal and external amp hour rating should not
exceed 360 amp hours.
• It is recommended to use at least 6 AWG cable or larger to connect additional batter-
ies to the Solar e Power Cube when drawing full power from the Inverter. Heavy cables
reduce voltage loss in the cables. Typical automotive jumper cables are sufficient.
• Install 100A fuse in positive line.

External Battery Connection Procedure

1. Turn OFF the Battery Disconnect Switch.
2. Locate the Battery Terminals above the wheels.
3. Install 100A fuse in positive line.
4. Loosen the Battery Terminal covers and connect the batteries using either ring terminals
or jumper cable clamps. Make sure the connection is secure.
5. With a voltmeter, verify that the battery voltage is correct at the terminals.
6. Turn ON the Inverter and observe the external battery voltage.
7. Turn ON the Solar e Power Cube Battery Disconnect Switch if batteries are connected.
CAUTION—BATTery DIsChArge:
With the Battery Disconnect Switch OFF, the Digital LED Voltmeter shows external battery voltage
to the Inverter. It is important to monitor the external battery voltage to prevent battery over-
discharge.

Bypassing The Internal Battery

The Solar e Power Cube's internal battery can be bypassed to use the Inverter or battery charg-
ing functions without using the internal battery. This feature can be used if the internal battery is
not available to power AC or DC appliances. To bypass the internal battery:
1. Turn OFF the Battery Disconnect Switch.
2. Connect external batteries to the Battery Terminals.
21
www.wagan.com
®

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2547

Table des Matières