9.3.2.
Window "hardware configuration"
16
english
Type 7616
Dosingsystem(Optional)
The dosing system can be operated with or without PC.
If operation is without a PC, the control frequencies set in this
window (in fields 1-3) are used.
For this mode, additional configuration of the hardware is required.
Menu description
panel "pumps"
number
Selection of the dosing unit 1 / 2
Control frequency of pump 1 in mode A
1
speed
1. Control frequency in mode B
[cycles/
2
2. Control frequency in mode B
min]
3
3. Control frequency in mode B
Device is connected with PC; the control is
Mode A
1)
performed via the software.
Device is in standalone mode.
The control takes place via the configurations that
were stored in the hardware.
The change-over of the hardware takes place via
Mode B
2)
jumpers.
Additional information on the change-over of the
hardware can be found in the following chapter
"Hardware".
default
Setting of the flow direction for dosing unit 1 / 2
direction
(direct / reverse – forward / reverse)
stop after xx
The respective dosing unit stops after xx cycles
cycles
tuning
Configuration of the control diagram
1)
2)
2)
2)