Models With Emergency Reset (Bbpr-Bb40); Description - Burkert 3003 Manuel D'installation Et D'utilisation

Masquer les pouces Voir aussi pour 3003:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
Models with emergency reset (BBPR—BB40)
Actuators with battery backup position recovery system (on-off wiring mandatory)
Models with emergency reset (BBPR—BB40) integrate a battery pack monitored by an electronic board inside the actu-
ator. Its function is to relay in case of power supply failure on terminal PIN 1,2 and 3 of the actuator. The BBPR system
can be set on different position like normally open (NO) or normally closed (NC). It depends on the application.
The electronic board monitors the battery pack and check the status of battery (cycle load and failure)
If a battery failure is detected , a contact on PIN 65 and 66 switch off. It's possible to use this contact to be aware that
there is a failure on battery in the actuator without remove cover and plan the replacement.
BBPR option requires ON/OFF mode.
Loading electronic board
LED

DESCRIPTION

D19
L1
Actuator operating into opening
green
D18
L2
Actuator operating into closing
red
Battery status :
ACT
Slow blinking (1s) : battery charged.
L3
green
Rapid blinking (0.5s) : battery charging
Error detected:
Timestamp memory empty/scheduler selected
ERROR
Clock failure
L4
red
Excessive temperature
Excessive torque
HORO
L5
Orange Weekly scheduler functioning mode
MANU
L6
Orange manual / Bluetooth
WIRE
L7
Orange Electric wiring mode
CONNECTEUR
C1
17 (-) · 18 (+)
C2
F (+) · F (-) · T (+)
C3
A · B · C
1)
C4
D3 · D4
1)
C5
65 · 66
C6
A · 0 · B
®
J1
Bluetooth
activation jumper
1) The auxiliary cables must be connected to inside installation only
The factory default configuration is "normally closed"
Following a power failure, the BBPR unit will reset after 4 minutes
3003 • Rev. 2109/03 • 00809466
®
functioning mode
DESCRIPTION
power supply connector
Battery unit connector
Motor connector
Failure feedback connector
Charging feedback connector
RS485 connector
L4
J1
L3
C3
C2
C1
Battery voltage
Battery capacity
Charging current
initial battery charge duration
Charging status feedback relay
Failure feedback relay (D3/D4)
Temperature
L6
C6
L5
L7
L1
C4
L2
C5
14.4 V DC
600 mAh
180 mA
3,5 h
24 V DC - 1 A max
24 V DC - 3 A max
-10 °C to +40 °C
23

Publicité

Table des Matières
loading

Table des Matières