Current
Thickness
(A)
4 mm
---
6 mm
---
¼ "
---
8 mm
---
10 mm
60
½ "
60
15 mm
60
¾ "
60
20 mm
60
25 mm
60
1 "
60
30 mm
60
1 ¼ "
60
35 mm
---
1 ½ "
---
Electromagnetic Compatibility (EMC)
This machine has been designed in accordance with all relevant directives and standards. However, it may still generate
electromagnetic disturbances that can affect other systems like telecommunications (telephone, radio, and television) or
other safety systems. These disturbances can cause safety problems in the affected systems. Read and understand
this section to eliminate or reduce the amount of electromagnetic disturbance generated by this machine.
This machine has been designed to operate in an industrial area. To operate in a domestic area it is
necessary to observe particular precautions to eliminate possible electromagnetic disturbances. The
operator must install and operate this equipment as described in this manual. If any electromagnetic
disturbances are detected the operator must put in place corrective actions to eliminate these disturbances
with, if necessary, assistance from Lincoln Electric.
Before installing the machine, the operator must check the work area for any devices that may malfunction because of
electromagnetic disturbances. Consider the following.
•
Input and output cables, control cables, and telephone cables that are in or adjacent to the work area and the
machine.
•
Radio and/or television transmitters and receivers. Computers or computer controlled equipment.
•
Safety and control equipment for industrial processes. Equipment for calibration and measurement.
•
Personal medical devices like pacemakers and hearing aids.
•
Check the electromagnetic immunity for equipment operating in or near the work area. The operator must be sure
that all equipment in the area is compatible. This may require additional protection measures.
•
The dimensions of the work area to consider will depend on the construction of the area and other activities that are
taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
•
Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take
additional precautions such as filtering the input supply.
•
The output cables should be kept as short as possible and should be positioned together. If possible connect the
work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting
the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
•
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.
Technical Specifications
Input Voltage
400V ±15%
Three Phase
English
TH1025
Speed (cm/min.)
MILD
ALUMINUM
STEEL
---
---
---
---
---
---
---
---
119
206
91
157
72
122
48
75
43
65
26
36
25
35
---
22
---
16
---
---
---
---
Input Power at Rated Output
TH1025
TH1538
Current
STAINLESS
(A)
STEEL
---
---
---
---
---
---
---
---
105
---
77
---
55
100A
40
100A
36
100A
17
100A
16
100A
---
100A
---
100A
---
100A
---
100A
INPUT
4.3kW @ 100% Duty Cycle
7.1kW @ 40% Duty Cycle
7.1kW @ 100% Duty Cycle
13.7kW @ 40% Duty Cycle
6
TH1538
Speed (cm/min.)
MILD
ALUMINUM
STEEL
---
---
---
---
---
---
---
---
---
---
---
---
180
223
117
152
106
140
70
98
68
95
50
73
45
66
38
55
32
48
Frequency
50/60Hz
STAINLESS
STEEL
---
---
---
---
---
---
147
99
91
63
61
46
42
36
31
11/04
English