UTILIZATION MANUAL
indicated as "
". To select the filtering program you
FC
can choose between:
= 24 hours filtering
FC
= 2 hours filtering and 10 hours stopped.
F2
= 4 hours filtering and 8 hours stopped.
F4
= 6 hours filtering and 6 hours stopped.
F6
= 8 hours filtering and 4 hours stopped.
F8
The default filtering time is 2 hours (
For filtering time press "TEMP" y then "JETS".
Press "TEMP" again to adjust and then press "JETS" to
exit programming mode.
5.9. PROTECTION AGAINST FREEZING
In the event the temperature sensors detect a drop of
temperature below 7ºC, the resistance and the
filtering pump will connect automatically to prevent
the water from freezing as this could damage your
Spa.
The equipment will be connected for 4 minutes after
the temperature reaches 7ºC.
In colder climates, an additional temperature sensor
can be added this way we protect the Spa when
freezing conditions are not detected by a standard
sensor.
).
F2
+
7
EN