3. TABLE OF TECHNICAL DATA AND MARK
The CE mark certifies that the
actuator conforms to the essential
health and safety requirements
laid down by European product
directives. The CE mark can be
identified by the relevant adhesive
label applied to the outside of the
product, on which are shown some
of the data shown in the following
table:
4
MCU (Mowin Control Unit)
Item radio
Item standard
Power Supply
Index protection
Relay contact capacity
Dimensions
Weight
Operating temperature
CONNECTION OF CN1 TERMINAL BOARD
1 - 230 V line input (Phase).
2 - 230 V line input (Neutral).
3 - Closing/Upward movement motor output.
4 - Shared motor output.
5 - Opening/Downward movement motor output.
CONNECTION OF CN2 TERMINAL BOARD
1 - Sun sensor power supply output 24 Vac.
2 - Sun sensor input "S" (NO).
3 - Rain sensor input "R" (NO).
4 - Shared GND Signal input / 0 Vac output.
5 - Wind sensor input "W".
6 - T1 local Closing/Upward movement button
input (NO).
7 - T2 local Opening/Downward movement
button input (NO).
8 - Shared GND Signal input.
9 - T3 general Closing/Upward movement button
input (NO).
10 - T4 general Opening/Downward movement
button input (NO).
11 - Earth antenna input.
12 - Antenna hot pole input.
MX00 AU 02H 0W 00
MX00 AU 03H 0W 00
230 Vac - 50/60 Hz
IP54
12 A
110x121x47 mm
374 g