6.
LINER LOCKING TRACK
Before the liner may be fitted to the P-PSC pool, a female extruded profile (the liner track) must be
fitted to the top of the panel to accept the male extrusion or bead welded to the edge of the liner.
The liner lock track comes in 2 m long straight strips and 4 corner pieces provided with the kit. Begin
installation of the track with the 4 corners. Screw these into position using self tapping screws or
rivets after piercing a corresponding hole in the upper edge of the panel. Next, install the straight
strips between the corners fixing in them in position with self tapping screws or rivets every 20 to
25 cm. The track should be flush with the front surface of the panel on the pool side. The seams
between the strips should not coincide with the seams between the panels.
NOTE:
Panel positioning should be completed before the track is installed. However if, during track
installation, it is found that positioning is not quite perfect, remove the self locking key from a
supporting brace and slide a lever under the panel to perform the slight manipulations necessary.
Silicon bead, Ø approx 4 mm
PISCINES P-PSC
Conventional
liner lock
profile
Panel
Extrusion
Special P-PSC
liner lock
profile
Once
the
panels
assembled with their supporting
braces, the liner track has been
installed and all readjustments have
been completed, block the assembly
in position by pouring mortar behind
the panels. Take care to ensure that
the supporting braces are encased.
The purpose is to increase the
strength and stiffness of the panels
and prevent infiltration during heavy
rain.
2020/05 - Indice de révision : B - Code : 37101
Extrusion
Screw
or
rivet
Screw
or rivet
(Optional)
Fitted
with
mallet
nb
have
been
39/48