Resetting All Values (Reset) - Balluff BTL7-A/C/E/G-M-A/B/Y/Z8-NEX-S32/KA Série Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BTL7-A/C/E/G _ _ _ -M _ _ _ _ -A/B/CD/Y/Z(8)-NEX-S32/KA _ _
Micropulse Transducer - Rod Style
10

Resetting all values (reset)

NOTICE!
Interference in function
Resetting the values while the system is running may
result in malfunctions.
► Stop the system before performing the reset.
The reset function can be used to restore all the settings to
the factory settings. For a reset the magnet may also be
located outside the measuring range.
1. Activate buttons
► Hold down any button for at least 3 s.
► Release buttons.
► Within 1 s, hold down
at least 3 s.
⇒ Output indicates error value.
⇒ Buttons are activated.
If an error or an interruption occurs while
activating the buttons, allow a wait time of 12 s
before retrying.
2. Reset
Œ
► Hold down
and
⇒ Output indicates null value.
⇒ All values are reset.
► Release buttons.
⇒ Current position value is displayed.
⇒ Buttons are locked.
22
english
Œ
and
simultaneously for
for at least 6 s.
LED legend:
LED display
LED1 LED2 At 0...10 V
1
2
> 3 s
< 1 s
> 3 s
1
2
> 6 s
1
2
LED not on
LED green
LED flashing green
LED 1 and LED 2 flashing green-red
simultaneously
Ignition protection
"nA" and "tb"
Displayed values (example)
At 4...20 mA
5.39 V
10.80 mA
5.39 V
10.80 mA
10.00 V
3.60 mA
0.00 V
4.00 mA
8.43 V
15.67 mA