4. Remove access cover from the gas pressure regulator.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
Gas pressure regulator
5. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
6. Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the "LP" or "NAT" position.
7. Turn over the spring retainer so the "NAT" is showing on the
bottom.
8. Snap the spring retainer back into the cap.
9. Reinstall the cap onto the regulator.
E
D
A. Access cap
B. Gasket
C. Gas pressure regulator
A
B
C
D. Spring retainer
NAT position
E. Spring retainer
LP position
To Convert Standard Surface Burners
1. Remove burner cap.
®
®
2. Using a T20
TORX
screwdriver, remove the burner base.
3. Apply masking tape to the end of a 7 mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Press nut driver down onto the gas orifice spud and remove
by turning it counterclockwise and lifting out. Set gas orifice
spud aside.
A
B
A. Igniter electrode
B. Gas tube opening
C. Burner cap
D. Burner base
4. Natural gas orifice spuds are stamped with a number on the
side. Replace the LP gas orifice spud with the correct Natural
gas orifice spud.
A. Stamped number
Refer to the following chart for the correct Natural gas orifice
spud placement.
Natural Gas Orifice Spud Chart for Standard Surface Burners
Burner Location
Burner Rating
Right front
6,000 Btu/h
Left front
14,000 Btu/h
Right rear
12,500 Btu/h
Left rear
6,000 Btu/h
5. Place LP gas orifice spuds in plastic parts bag for future use
and keep with the package containing literature.
6. Replace burner cap.
7. Repeat steps 1-6 for the remaining burners, except for the
TripleTier
®
Flame burner (on some models). See "To Convert
®
TripleTier
Flame Burners" in the "Natural Gas Conversion"
section.
C
D
A
Size
1.10 mm
1.70 mm
1.61 mm
1.10 mm
23

Publicité

Table des Matières
loading

Table des Matières