English
10.1 Fault signals
Code no.
Faults
E04
Undervoltage Power supply too low
E05
Overvoltage
E07
Generator
operation
E10
Blocking
E11
Dry run
E21
Overload
E23
Short-circuit
E25
Contacting/
winding
E30
Module
overheat
E36
Module
defective.
If the fault cannot be remedied, please consult the after-
sales service.
32
Causes
on mains side.
Power supply too
high on mains side.
Water is flowing
through the pump
hydraulics, but pump
has no mains voltage.
Rotor blocked.
Air in the pump
Sluggish motor
Motor current too
high.
Winding defective.
Module interior too
warm.
Electronic compo-
nents defective
Remedies
Check mains voltage.
Check mains voltage.
Check mains voltage.
Contact customer
service.
Check water quan-
tity/pressure.
Contact customer
service.
Contact customer
service.
Contact customer
service.
Check operating con-
ditions in chapter 5.2.
Contact customer
service.
Speck 07/2012