Pos: 73 /Technische Dokumentation/Pumpendatenblatt/Motorsteuerung/Eco Motion/Fehlercodes @ 2\mod_1434094368813_370.docx @ 32747 @ @ 1
Fault codes
No.
E0
E1
E2
E3
E4
E5
E8
E9
E10
E11
E12
E13
E14
E16
E17
E18
E19
E20
E31
Pos: 74 /Technische Dokumentation/Allgemeine Module/#### Seitenumbruch #### @ 0\mod_1426069111812_0.docx @ 891 @ @ 1
05|2016
Fault name
Motor PTC
Motor PTC
Motor PTC
Temperature
Short-circuit/
overcurrent
Temperature
Input voltage
Input voltage
Intermediate circuit
voltage
Intermediate circuit
voltage
Intermediate circuit
voltage
Motor current
I²t
Overload protection
Phase fault
Parameter
Analogue In
Motor current
Global error
Fault description
Motor PTC open
Motor PTC short
Motor
overtemperature
Overtemperature
power module
Motor short-circuit or
overcurrent
Overtemperature
rectifier
Input voltage too low
Input voltage too
high
Intermediate circuit
voltage too low
Intermediate circuite
voltage too high
Intermediate circuit
voltage fault
Motor current too
high
I²t overload
Overload protection
failed
Input phase missing
Parameter error
Analouge input lies
outside the defined
range
Motor current too
high
General error allert
Possible cause/
remedy
Motor PTC not
connected
Motor PTC short-
circuited
Check the cooling
Ambient temperature
which is too high
Check load
Ambient temperature
which is too high
Check supply
voltage
Check suplly voltage
Check load
Check supply
voltage or generator
operation
Check supply
voltage
Check load
Check load
Contact service
Check supply
voltage
Check parameter
assignment
Check analogue
input
Check load
EN 43