OUTER DIMENSIONS
In the drawings below, all the dimensions are displayed in mm.
Sufficient clearance around the hob is essential for a safe use of the hob. Check that there is sufficient clearance. The minimum
distance of the hob to a cooker hood should be at least 650 mm.
GAS CONNECTION
Caution!
The hob should be connected to a gas supply of the particular type of gas that the appliance is manufactured to
function with. Information about the type of gas that the hob has been adapted to by the factory is shown on the
rating label. The hob should be connected exclusively by an appropriately authorised fitter and only that person has
the right to adapt the hob to a different type of gas.
Fitting guidelines
A fitter should:
• have a gas fitter's authorisation;
• be acquainted with the information included on the rating label of the hob about the type of gas to which the hob
is adapted; the information should be compared with the gas supply conditions at the place of installation;
• check:
- airing efficiency, that is effeciency of air exchange in the rooms;
- tightness of gas fitting connections;
- effectiveness of alle functional elements of the hob;
- if the electricity supply is adapted to function with a safety ground lead (zero).
• regulate the settings of the rotary buttons for the gas burners, to ensure proper operation of the spark ignition and gas
leak safety.
Caution!
The hob may only be connected to a liquid gas cylinder of the existing gas supply by an authorised fitter, observing all safety rules.