11. Weather Station Operation
a) Switching Displays
• Briefly push the button "SET"; the wind speed flashes.
• Use the button "+" or "MIN/MAX" to switch the display between:
(no display)
Average wind speed
"GUST"
Gust speed
• Briefly push the button "SET"; the rain volume flashes.
• Use the button "+" or "MIN/MAX" to switch the display between:
"1h"
Rain volume of the last hour
"24h"
rain volume of the last 24 hours
"week"
Rain volume of the last week
"month"
Rain volume of the last month
"TOTAL"
total rain volume since the last reset
While the corresponding display is present, you may reset it to "0.0" by keeping the button "SET" pushed
for 2 seconds. The respective shorter measuring duration is also automatically reset.
Example: If the weekly rain volume ("week") is reset, the rain volume of the last hour ("1h") and the last 24
hours ("24h") is reset to "0.0" as well.
• Briefly push the button "SET"; the outdoor temperature flashes.
• Use the button "+" or "MIN/MAX" to switch the display between:
"TEMP"
Displays the measured outdoor temperature
"WIND CHILL" Displays the wind chill temperature
This temperature value is calculated from the interrelation of temperature and wind speed.
For temperatures below +10 °C, higher wind speeds mean that the temperature perceived on the
human skin is lower than the actual temperature (example: Present outdoor temperature -20 °C,
wind chill temperature -34 °C at a wind speed of 40 km/h).
"DEW POINT"
Displays the dewpoint temperature
The dewpoint is the temperature to which condensate just starts to form on an object.
• Briefly push the button "SET" to leave the setting mode (alternatively do not push any button for 30 seconds).
34